Evercrete Pavishield® - Penetrating Concrete Floor Sealer & Hardener
Total protection of your floor
With Pavishield® you can improve the life of your industrial flooring because it is the only product able to protect the concrete at 360 degrees, even outdoor. With Pavishield® you can prevent the deterioration of the concrete from the first minutes using it as curing compound. Then your floor will be protected also from atmospheric agents, from deicing salts, from superficial wear and from rising damp.
What is Evercrete Pavishield?
It is a spray-applied concrete floor sealer made from a blend of modified liquid silicates and special additives, based on Ecobeton's original proprietary formula. With decades of experience in the field and millions of square metres of industrial concrete treated, Pavishield® is the ultimate waterglass concrete protection.
A single product, a unique product
Curing compound, dustproof and anti-deterioration in a single product, with only one treatment. Thanks to its innovative and ecological formulation Evercrete Pavishield® is a permanent treatment with which you can reduce maintenance costs by more than 60%. Thanks to its versatility, the designer can guarantee reliable and certified results.
Key Benefits for Industrial Concrete Floors
Curing compound: When sprayed on fresh concrete, Evercrete Pavishield® slows water evaporation from the concrete mass, dramatically reducing the risk of cracks and fissures from concrete shrinkage.
Hardener: Increases surface hardness and wear resistance more than 30% on concrete of any age. Used as a concrete hardener and sealer, it serves also as a dustproof sealer.
Protection: Shields against weathering, deicing salts, freeze-thaw cycles, and exposure to aggressive physical and chemical agents such as motor oil and fuel. Pavishield reduces the absorption of oils and grease up to -67%.
Deep penetration into the concrete mass up to 34mm guarantees permanent protection and lasting effect, without altering the surface (slipperiness, colour, texture, etc.). If desired, you can even install any other overlay on top of a concrete floor treated with Pavishield® penetrating concrete sealer.
A certificated experience
Evercrete Pavishield® is an EN 1504-2 concrete sealer, CE marked, and complies with the principles 1.2 (Ingress protection) and 5.2 (Physical resistance). The LCA (Life Cycle Assessment) study was conducted in accordance with the EN 15804 standard for EPD in construction works. The VOC content is zero for LEED/BREEAM compliance.
Technical Performance Data
| Property | Result | Reference Standard |
|---|---|---|
| Resistance to surface compression | 30% mean increase | UNI 9944 |
| Adhesion to binders, resins and paints | Improved | AMA-83 Sweden |
| Efflorescence susceptibility | None | - |
| Absorption of oils and grease | Decreasing of 67% | - |
| Anti-evaporation | Excellent results | ASTM C-309-74 |
| Freezing and thawing resistance | 300 cycles without damage | UNI 7087/72 |
| Property | Result | Reference Standard |
|---|---|---|
| Abrasion resistance | Improvement > 30% | EN 1504-2 |
| Capillary absorption and permeability to water | ≤ 0.1 kg/m2 ∙ h-0.5 | EN 1504-2 |
| Chemical resistance | No visible defects | EN 1504-2 |
| Impact resistance | Class III > 20Nm | EN 1504-2 |
| Fire classification | Euroclass A1 | EN 1504-2 |
| Depth of penetration | > 10mm | EN 1504-2 |
Max Certified Penetration Depth
Freeze/Thaw Cycles Passed
Water-based & Non-Toxic
How to Apply Evercrete Pavishield
Step by Step
Usually, silicate concrete sealer cannot be applied directly to fresh casts because the silicate reacts quickly with cement and “burns” the surface of the floor. The exclusive formulation of Pavishield turns a potential problem with silicates into a great opportunity to use the product as a concrete curing compound, enhancing surface properties and reducing concrete floor cracking.
As soon as you can step over the concrete floor, for example, just after the power-trowel has terminated its job, you can spray the first coat of Evercrete Pavishield® all over the surface, wetting the area uniformly. We recommend a low-pressure sprayer, as used in agricultural environments to apply treatments to the vineyard.
If you plan to install control joints by sawing the concrete floor, we suggest applying the second coat after this operation. Be careful that the concrete saw cut will generate cement dust; clean it thoroughly before proceeding with the penetrating concrete sealer application to avoid a reaction.
If you are treating a concrete floor indoors, we also recommend rinsing the full area with a washer-dryer machine to prevent minor aesthetic issues in case of localised product stagnation. When applying the waterglass concrete treatment outdoors, this is not strictly necessary.
Why Pavishield® Outperforms Traditional Systems?
Comparative analysis based on 2026 structural performance data
| Technical Feature | Evercrete Pavishield® | Resins / Coatings | Standard Silicates |
|---|---|---|---|
| Peeling/Delamination Risk | None (Deep Penetrating) | High Risk | Rare |
| Fresh Concrete Curing | Integrated (Anti-evaporant) | Not Applicable | Partial |
| Rising Damp Barrier | Guarantees a RH < 85% | Causes Blistering | Limited |
| Service Life Maintenance | Near Zero (Permanent) | High Maintenance | Moderate |
Trusted by Infrastructure Leaders
From the Airbus A380 Hangar in Paris to International Airports and Michelin-star Wineries.